| Ford 4 cylinder marine diesel engined generator sets |
3000RPM, 50Hz (3600RPM, 60Hz) models XLD - 29 KW (36 KVA) Max. FSD - 39 KW (49 KVA) Max. | 1500RPM, 50Hz (1800RPM, 60Hz) models XLD - 14 KW (18 KVA) Max. FSD - 21 KW (26 KVA) Max. NHD 450 - 45 KW (56 KVA) Max. |
| |
| Design Features |
Engine Well proven, normally apsirated. Suitable for generator set applications. | Fuel system Rotary injection pump with electronic speed control. | Reliability Meets high reliability and durability demands, self air-purging fuel pump. | Serviceability Low maintenance requirements, longer service intervals. |
| |
| Standard specifications |
Standard items Jabsco sea water pump. Bowman combined heat exchanger and water cooled manifold. Engine oil cooler in fresh water circuit (not XLD/FSD LP/MP engines). Water injected exhaust outlet. Engine mount brackets with adjustable rubber mounts Transmission attachment parts. Speed control cable connection. Hot test after marinisation. Owner's handbook . 12V electric starter. 12V alternator. Low oil pressure switch. Over temperature switch. Dual tone alarm sounder | Optional items Geabox oil cooler Gear control cable connections Dual station control connections Calorifier connections Sump pump kit Heavy flywheel Auxilliary fuel filter All-speed governing in lieu of power/torque Armoured feed and return hoses "Inland waterways" fuel pipes On-board spares kit Workshop manual Parts identification manual | Instrumentation and electrical options Start/run switch, warning lights and 4M harness Tachometer (with hours), hour meter, temperature, oil pressure, battery voltage, fuel, rudder angle and gearbox pressure gauges, standard or custom made instrument panels High output alternator, Sterling "smart" alternator control, load split relay, 4M harness extension, intake blockage sensor, fly-bridge alarm & re-start panel, battery cable kit |
| |
| Variation to standard specifications and extra optional items for this engine type |
Additional standard items Electric run/stop control Single-groove power take-off pulley (not NHD) Full power load test Water-in-fuel sensor (not NHD) Automatic shut-down on low oil pressure or high water temperature | Optional items High-rise exhaust Steel base frame for transportation/installation | Optional A.C. Instruments Voltmeters, ammeters and frequency meters of suitable ranges. click to see options and prices |
| |
| Generator specifications |
Alternator Meccalte EC series brushless alternators. Compliance standards: IEC34-1, CEI2-3, BS4999-5000, VDE0530. Choice of single or three phase and 50 or 60Hz. | Voltage regulation Maintained within ± 1% with load from 1-100%, speed from -2% to +5% and power factor 0.8 to 1% and balanced load. Electronic engine speed control keeps engine speed ± 2%. | Voltage Stock alternators are 12-wire and normally supplied for single phase 120V-60Hz or 230V- 50Hz, or for 3 phase 230V-60Hz or 400V-50Hz, but can be reconnected to other configurations and the voltage adjusted ± 10% by means of the regulation screw. Alternators supplied as 3-phase will have only 60% power output if re-connected as single phase, unbalanced. |
| |
Engine and generator specifications may vary as improvements are introduced. Lancing Marine reserve the right to alter specifications without notice |
| |
| Detailed specification |
| Engine model | Ford XLD | Ford FSD | Ford XLD | Ford FSD | NHD 450 | | RPM Continuous | 3000 | 3000 | 1500 | 1500 | 1500 | | Aspiration | Natural | Natural | Natural | Natural | Natural | | Engine electrics (earth return) | 12V | 12V | 12V | 12V | 12V | | Alternator Amps | 55 | 55 | 55 | 55 | 70 | | Minimum battery size | 65AH | 85AH | 65AH | 85AH | 143AH | | Starter cable mm2 | | Length 0.6M | 25 | 40 | 25 | 40 | 70 | | Length 1.2M | 40 | 70 | 40 | 70 | 95 | | Installation angle maximum (degrees) | | Front up | 15 | 15 | 15 | 15 | 30 | | Front down | 5 | 5 | 5 | 5 | 5 | | Heeling angle | 15 | 15 | 15 | 15 | 35 | | Maximum fuel consumption (lit/Hour) * | 9.5 | 12.5 | 5 | 5.7 | 17.2 | | Fuel feed diameter (mm) | 8 | 8 | 8 | 8 | 8 | | Fuel return diameter (mm) | 8 | 8 | 8 | 8 | 8 | | Exhaust diameter (mm) | 50 | 50 | 50 | 50 | 75 | | Water intake diameter (mm) | 28 | 28 | 28 | 28 | 28 | | Generator model - single phase | ECO31-3S/2 | ECO31-2L/2 | ECO28-2L/4 | ECO32-2S/4 | ECO34-1S/4 | | Generator model - three phase | ECO31-1S/2 | ECO31-3S/2 | ECO28-S/4 | ECO28-2L/4 | ECO32-2L/4 | | Output maximum Kw (KVA) | 28 (35) | 41 (51) | 14 (18) | 19 (23) | 43 (54) | | Total weight Kg - single phase | 389 | 499 | 328 | 462 | 761 | | Total weight Kg - three phase | 356 | 467 | 292 | 380 | 716 | | Dimensions (mm) L x W x H - single phase | 1291 x 565 x 635 | 1506 x 685 x 758 | 1208 x 565 x 635 | 1380 x 685 x 758 | 1653 x 660 x 830 | | Dimensions (mm) L x W x H - three phase | 1291 x 565 x 635 | 1401 x 685 x 758 | 1128 x 565 x 635 | 1305 x 685 x 758 | 1620 x 660 x 830 | | Boatbuilder price - single phase | £5219 | £5636 | £5003 | £5219 | £7611 | | - three phase | £5076 | £5303 | £4936 | £5087 | £7179 | | Optional extras | Steel base frame £100 - £225 | Oil drip tray £80 - £110 | - | | All prices are quoted net of VAT (value added tax) which will be added at the appropriate rate | |
All dimensions are in mm unless stated. ± 5%. Outputs at 1800 and 3600 RPM are approximately 20% more than listed. * 60Hz models have approximately 20% greater power output and fuel consumption. |
| |